Symptom

Possible Cause

Solution

Platform rises slowly

Air bladder or connecting
ducts punctured

Check air bladder and ducting replace as needed

Damaged or restricted
ducting

Replace damaged ducting or remove restriction

Air intake clogged

Remove intake filter, clean or replace as needed

Dock leveler binding

Check for visible obstructions that could cause
binding. Remove obstructions. If no obstructions
found, call Poweramp Technical Services. See inside
back cover for phone number and address.

Platform does not rise to
full height.

See Platform Rises Slowly

See Platform Rises Slowly
See Periodic Maintenance in the Maintenance
section.

Platform DOES rise to
full height, but lip DOES
NOT extend or extend
fully.

Lip actuator spring needs
additional tension.

Inspect lip actuator chain, repair or replace as
needed.

Lip extends but does
not remain extended as
leveler drops.

Lip latch spring needs
additional tension.

Air bladder damaged

See Adjustment Section: Lip Latch Spring.

Increase tension as needed to keep latch
engaged.

Clean any debris from lip latch area.

Lubricate as instructed in maintenance section.

• Replace air bladder