ADJUSTMENT AND TESTING

Dock Leveler at cross traffic position. Lip fully
folded, inside keepers. (Lip also fully folded when
leveler on maintenance prop.)

1. Target not in sensing area of switch.
2. Switch "OFF" = open (no signal sent to load).
3. Switch indicator light "OFF".
4. The dock leveler does not automatically raise &
return to dock.

Figure 15

LIP
KEEPER

Dock leveler at full below dock position. Lip
partially extended, outside keepers.

1. Target in sensin area of switch.
2. Switch "ON" = closed (signal sent to load).
3. Switch indicator light "ON".
4. The dock leveler automatically raises, after
an approximate 6 second delay, & returns to
dock**.

LIP KEEPERS

Figure 16

Dock leveler on truck bed. Lip fully
extended.

1. Target not in sensing area of switch.
2. Switch "OFF" = open (no signal sent to
load).
3. Switch indicator light "OFF".
4. The dock leveler does not automatically
raise & return to dock.

Figure 17

**The 6 second delay is in the switch. The dock leveler will raise after
approximately 6 seconds after the target is sensed by the switch.