15. Depress and hold the raise button until the maintenance prop can be positioned

properly. This will require 2 people should a remote raise button be unavailable.

16. With the maintenance prop supporting the platform, remove the lifting lugs.

17. Depress the raise button again until you hear the maintenance prop return to its

stored position.

18. Cycle the dockleveler 4 or 5 times throughout its complete operating range to

assure proper operation.

19. Install bumpers.

6

INSTALLATION

Always barricade the
work area to prevent
unauthorized use of
the unit before
maintenance is
complete.

Always lock off all
electrical disconnects
after raising platform
and setting mainte-
nance prop when
service under the unit
is required. More
than one electrical
disconnect switch
may be required to
de-energize the
equipment.

Always stand clear of
the dockleveler lip
when working in front
of the unit.

WARNING