23

4111-0012 — Oct.2007
Dec.2008

MAINTENANCE

Regular maintenance must be performed on a
weekly and quarterly schedule.

Weekly Maintenance

• Operate the dock leveler through the complete

operating cycle to maintain lubrication.

NOTE: To thoroughly inspect the platform hinge

area, put the platform in the full below-dock
position.

• Inspect the platform lug and the lip lug areas. The

hinge areas must be kept free of dirt and debris.
Build-up of foreign material in the hinge areas will
cause abnormal operation.

Quarterly Maintenance

• Lubricate the following areas with light weight

machine oil:

(B)(D)- Platform lug area (apply oil to top of all

platform hinges when platform is at the full
below-dock position)

• Lubricate the following areas with white lithium

grease:

(A)— Lip lug area (apply oil to each of lip and

platform lugs when platform is at the full
below-dock position and lip is folded)

(C)(E) - Both Hoist and Lip cylinder trunnions

• Check reservoir fluid level (Q):

1. Put the dock leveler platform at the full

above-dock position, engage prop.

2. Turn OFF all electrical power to the leveler.

3. Measure fluid level. The fluid level should be

approximately 3 in. (76.5 mm) (N) from top of
reservoir (M) with platform raised on the
maintenance prop.

4. Add hydraulic fluid if necessary. Use only

recommended fluid.

5. Turn ON electrical power to the leveler.

6. Return the platform to the cross-traffic position.

Before performing any maintenance under the
dock leveler, lock the electrical power source in
OFF position and lock the maintenance prop in the
service position using an approved locking device.
(See Service Dock Leveler Safely in this section.)

Failure to follow these instructions may result in
serious personal injury or death.

M -- Reservoir

P - Breather Cap

N- 3 in. (76.5mm)
From Top of Reservoir

Q - Fluid Level

IMPORTANT

Failure to properly lubricate the dock leveler will
cause abnormal operation of the leveler.

IMPORTANT

A low fluid level or the use of hydraulic fluids not
equivalent to the fluid types recommended, will
cause abnormal operation of the leveler and WILL
void warranty.