Installation details-automatic powerstop, Stop-tite overview stop-tite powerpack, Powerstop overview – Poweramp POWERSTOP 4.2009 User Manual

Page 8

Advertising
background image

6

4111-0014 — November 2006

Sept 2007

INSTALLATION DETAILS-AUTOMATIC POWERSTOP

LEVEL

11”

SECTION "A-A"

A

A

7

12

8

9

14

14

6

5

4

1

3

11

10

CONNECT TO BASE END OF RELEASE CYL.

BC

DESCRIPTION

NOTE

RC

CONNECT TO ROD END OF RELEASE CYL.

Capacitor Wiring Detail

Motor

Blue

Motor

Red

6

2

13

R.V. SET @

HYDRAULIC SCHEMATIC

105

M

650 PSI

RC

BC

1

1

1431-0011

Connector - 2-Screw

3/8

2

3

1431-0086

Insulated Terminial

16-14 AWG

3

2

2101-0017

Hex Head Capscrew

3/8-16 UNC X 1

4

2

2101-0140

Lock Washer

3/8

5

1

2751-0016

Cover - J-Box

4 X 4

6

1

3051-0058

Capacitor - Motor Start

64-77mF - 330V

7

2

6431-0001

Grommet

1-3/8 OD X 3/4 ID

8

2

9301-0164

Fitting Conn Str Thrd

#4 ORB X #4 JIC

9

1

9391-0009

Powerpac - PowerStop

1PH - 115V - 1/4 HP - 1 GPM

10

1

9392-0045

Cover - PowerStop

B CAD

11

1

9393-0025

Powerpac Mounting Weldment

B CAD

12

2

9904-0097

Hyd Hose Assy - 1/4"100R1 X 24.00

#4 JICF SWIVEL BOTH ENDS

13

1

R513-0050

Wire

16 GA RED X 5.00"

14

2

R598-0090

Split Flex Conduit

1/4" X 9.00"

BILL OF MATERIAL

QTY

ITEM

DESCRIPTION

PART NO.

SIZE

STOP-TITE Overview

STOP-TITE Powerpack

McGuire.

McGuire

STOP-TITE

STOP-TITE

AAL

Conduit, flexible or rigid, must be connected between the limit switch on the restraint and the powerpack. Wiring to and
from the restraint must be limited to restraint wires only. Do not run high voltage lines through the same conduit as restraint
wires. Conduit and associated hardware to complete wiring and mounting of powerpack are to be supplied by others.

POWERSTOP Overview

POWERSTOP Overview

Advertising