Battery installation , replacement and test, 2 battery test – PSA LIF5000 User Manual

Page 16

Advertising
background image

14

8.

BATTERY INSTALLATION , REPLACEMENT AND TEST

8.1.6 USE ONLY BATTERIES SPECIFIED ON THE LABEL .
8.1.7 Fold Red Battery Lever down into compartment with fresh replacement

battery. If the Red Battery Lever is not held down in the battery compart-
ment by the battery, the smoke alarm will not close and will not be opera-
tional. Battery can only be inserted in one direction, ensure polarity is correct.

WARNING: Use of inferior batteries or incorrect types may cause a malfunction of the
alarm. When replacing the battery and on reconnection of the detector to the base plate,
make sure that the detector is fully connected and flush with the base plate. Verify that
the Green LED is ON after reinstalling the alarm on the base plate.

8.2 Battery Test:

8.2.1 Switch off mains power. The Green LED on the smoke alarm will be OFF.
8.2.2 Test alarm by pressing on the Test Button for a few seconds. This should sound the alarm.
8.2.3 If the battery module has a fault, the alarm will chirp every 40 seconds.

8.2.4 Watch the Red LED for about 40 seconds. It should flash at least once.
8.2.5 Switch on mains power only when smoke alarm passes the above tests. The Green

LED on the smoke alarm will come ON.
NOTE: NO USER REPLACEABLE PARTS INSIDE.
NOTE: WEEKLY TESTING IS RECOMMENDED!

1298-7207-02_V1a:_ 2012.2.16 1:54 PM Page 14

Advertising