6-21 Communications

Registers (Cont'd)

Model Information

40300

Model
Read only
Returns the PLuS model number (5144, 6144, etc.).

40301

Revision
Read only
Returns the major software revision.

40302

Output Quantity
Read only
Returns the number of output channels (8, 9, 16, 17, 25, etc).

40303

Option Index
Read/write
Values: 1 - n
Used as index for reading installed controller options through the Option Register.

40304

Option
Read only
Values: 0 - n
Returns installed controller options as specified through the Option Index Register. A value of
'0' at index '1' means no options are installed.

Hardware Configuration

40305

Keyboard Quantity
Read/write
Values: 1, 2
Number of keyboards attached to PS-6000 controller.

40306

Increasing Direction
Read/write
Values: 0 = CCW, 1 = CW
Specifies the direction of rotation of the resolver (viewed from the shaft end) that will result in
an increasing numerical display of position.

40307

Scale Factor
Read/write
Values: 2 - 1024 (4096 with "-H" Option)
Scale factor used for pulse, position, and offset programming.

40308

Shaft Position
Read only
Values: 0 - ( Scale Factor - 1 )
Returns the current resolver shaft position, including the shaft offset.

40309

Shaft Offset
Read/write
Values: 0 - ( Scale Factor - 1 )
Offset that is added to raw resolver position to make Shaft Position.

40310

Analog Quantity
Read/write
Values: 0, 1, 2
Specifies the number of analog modules active.

40311

Resolver Type
Read/write
Values: 0 = Electro Cam, 1 = Other
Specifies type of resolver attached to controller.

40312

Program Select Mode
Read/write
Values: 0 = Binary, 2 = BCD, 1 = Gray code
Specifies how the program select inputs determine the active program.