Emergi-Lite Prestige Economizer Series - Recessed ceiling-mount User Manual

Important safeguards, Read and follow all safety instructions, Save these

Advertising
background image

Emergi-Lite

Tel: (888) 552-6467

Fax: (800) 316-4515

www.emergi-lite.com

04/11 750.1541 Rev. A

Prestige Series - Edge-Lit LED Exit Series

1/2

Prestige Series - Edge-Lit LED Exit Series

Flat trim AC, AC/DC and Self-Powered models

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should
always be followed including the following:

READ AND FOLLOW ALL SAFETY
INSTRUCTIONS

1. Do not use outdoors.
2. Do not let power supply cords touch hot surfaces.
3. Do not mount near gas or electric heaters.
4. Equipment should be mounted in locations and at heights where it will

not readily be subjected to tampering by unauthorized personnel.

5. The use of accessory equipment not recommended by the manufac-

turer may cause an unsafe condition.

6. Do not use this equipment for other than intended use.
7. All servicing should be performed by qualified service personnel.

SAVE THESE

INSTRUCTIONS

Installation Instructions

Turn off AC power.

Installation

1. Remove the proper knockout in the back box for the entry of the AC

wires.

2. Assemble the bar hangers (3) to the adjustment brackets (2) and the

adjustment brackets to the back box (see figure 2). Install the bar
hangers in the adjustment brackets . Mount the back box so that it is
flush with the ceiling surface.

3. Route AC unswitched circuit of rated voltage into the back box and

leave 6” of wire length.

4. Follow directions on the panel for chevron placement. (Note: for sin-

gle sided units with clear background place chevron on back of
panel).

5. Connect the incoming ground to the short ground wire provided in the

back box.

6. Electrical connection

a. Connect the long ground lead from the back box to the ground

lead from the trim plate assembly with the hardware provided.

b. Make the proper connections (see figure 3). Our system can

accept input voltages of 120 VAC to 347 VAC. For regular models
connect the purple (hot) and white (common) leads to the building
utility (Figure 3).

c. AC/DC Models only:
For DC portion: wire the red lead (+) to the positive DC input voltage
and the blue lead (-) to the negative DC input voltage. Note: DC input
voltage range is 6 volts to 24 volts.

Figure 1

Part List

1.

Back box

2.

Adjusment brackets (2)

3.

Bar hangers (2)

4.

Trim plate assembly

5.

Exit panel

Figure 2

Slots to receive
retention
springs

Advertising