AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)

PAGE 4 - 11

Chapter 4: Installation & Wiring

4.6.3.2 Output Data Format (From DATA-OUT 1 Port)

The example below shows the format of the DATA-OUT (1) port connected to a printer. Actual

data output format may vary depending on the configuration and set-up of this port using the AFC

User Console Software. The data field is selectable from as little as one output field to all available

data (see previous table for available data fields). Headers, footers & ASCII control characters are

all user configurable using the AFC User Console Software.

EXAMPLE ONLY – Actual data will depend on individual user set-up.

2007/09/26 09:17:57 SEQ01 [Input Data from DATA-IN if programmed here]
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG Acceptable Fastening
01 01 0.50 2 0.000 0.005 0.00 O

2007/09/26 09:19:36 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG Rejected Fastening
01 01 0.17L 0 0.000 0.000 0.00 X

2007/09/26 09:21:16 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG Reset Cycle
01 01 0.23L 0 0.000 0.000 0.00 * (Before fastening end)

2007/09/26 09:21:21 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG Cycle Stopped
01 01 0.17L 0 0.000 0.000 0.00 ! (Before fastening end)

2007/09/26 09:21:34 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG Abnormal
01 01 0.01 0 0.000 0.000 0.00 A05 (Showing abnormal code)

2007/09/26 09:21:21 SEQ01
SP PA TORQUE ANGLE 1RATE 2RATE OFSET JUG Spindle Bypassed
01 00 0. 0. 0. 0. 0.

Index

SEQ

: Sequence

1RATE

: 1st Rate

H

: High

SP

: Spindle

2RATE

: 2nd Rate

L

: Low

PA

: Parameter

OFSET

: Offset Torque

ANGLE

: Final Angle

JUG

: Judgment

Advertising