AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)

PAGE 4 - 15

Chapter 4: Installation & Wiring

(Continued)

[Table 1 – Sequence Selection]

Sequence

Select 3

Sequence

Select 2

Sequence

Select 1

Sequence

Select 0

Selected Sequence No.

OFF

OFF

OFF

OFF

1

OFF

OFF

OFF

ON

2

OFF

OFF

ON

OFF

3

OFF

OFF

ON

ON

4

OFF

ON

OFF

OFF

5

OFF

ON

OFF

ON

6

OFF

ON

ON

OFF

7

OFF

ON

ON

ON

8

ON

OFF

OFF

OFF

9

ON

OFF

OFF

ON

10

ON

OFF

ON

OFF

11

ON

OFF

ON

ON

12

ON

ON

OFF

OFF

13

ON

ON

OFF

ON

14

ON

ON

ON

OFF

15

ON

ON

ON

ON

16

4.7.3 Output Signals

The list below contains a description of the output signals available on the I/O interface. Further

output mapping can be found in the individual interface information (See Chapter 5). The

Multi-2 Unit is capable of providing over 570 Output signals to indicate the status of the Multi-2

Unit and of all the AFC1500 SAN Controllers connected to it (up to 31 controllers). These

signals are user configurable using the AFC User Console Software and may be programmed

on any designated output bit.

Main Multi Unit Output Signals

Total Reject

Output when the fastening result is a REJECT. Indicates that one or more

spindles have failed achieving the fastening limits. This output remains active

until the START signal or RESET signal is input.

Total Accept

Output when the fastening result is a ACCEPT. Indicates all spindles are

within fastening limits. This output remains active until the START signal or

RESET signal is input.

Abnormal

Output when an Abnormal condition occurs. This signal indicates that the

System has detected an internal fault, and can no longer proceed. The fault

maybe generated from a connected spindle during a self-check function.

Check the individual spindle status to identify which spindle is reporting the

abnormal condition. (see AFC1500 Operation Manual for troubleshooting)

The spindle reporting an abnormal may be bypassed to resume normal

operation, however, the bypassed spindle will be ignored and not run while in

bypass. An Abnormal condition must be corrected before the System will

resume normal operation. The RESET signal clears the abnormal condition.

Ready

Output when the system is in the READY condition. Indicates system is ready

to operate, and inputs are enabled. This signal is inactive (off) when the

BUSY output is active (on).

Busy

Output after a START signal is received, and active until the fastening cycle is

complete and the READY signal is output.

End

Output when a fastening cycle is complete. Remains active until the START,

RESET or REVERSE signal is input.

Sequence 0

Output confirmation of SEQUENCE SELECT 0~4 input selections.

Sequence bits are active according to what sequence is set from the

sequence select inputs. Used to confirm proper sequence before fastening

starts. Refer to Table 3.

Sequence 1

Sequence 2

Sequence 3