3.1.1 System Block Diagram Description

{ The System construction provides control for up to 24 spindles through the use of a single

Main Controller Unit.

{ Communication between the Main Controller Unit and up to 24 Axis Controller Units is

accomplished via a communication bus ribbon cable (MA/AA cable).

{ Tool assemblies connect to their respective Axis Controller Units via a set of three homerun

cables: Motor, Encoder, and Sensor / Preamp (Transducer) cables.

{ A color VGA CRT (or optional LCD) and keypad provide the interface required to monitor

and adjust System operations.

{ Discrete 24 VDC true low I/O on both the Main Controller Unit and the Axis Controller Unit

provide direct communications with the PLC, as well as individual spindle control via the
Axis Controller Unit discrete I/O.

{ Communication with additional devices is accomplished via:

(1) RS232 input port, (1) RS232 output port, (1) RS422 port, and (1) Centronics parallel
port.

Chapter 3: System Description