FEC AFC1200 User Manual

Page 9

Advertising
background image

)(& ,QF

200~230 VAC, 50/60 Hz, 3-phase input power connector.

AC-POWER

18

Six (6) dual-color LED indicators. Refer to Axis Unit Reject
Display Table on Page 3-11.

REJECT

17

Displays two-digit Parameter number and, as needed, will
override Parameter output to display an Abnormal code.
Refer to Chapter 9 for Abnormal display code descriptions.

PARM/ABN

16

Two-digit capability, Spindle number display. Determined
by the dip switch setting (reference Section 4.9.1).

SPDL

15

Type of information displayed is dependent upon the
selector switch setting on the ISA Main Controller Unit.
Refer to the Axis Unit Display Table on Page 3-11.

DSP 2

14

Type of information displayed is dependent upon the
selector switch setting on the ISA Main Controller Unit.
Refer to the Axis Unit Display Table on Page 3-11.

DSP 1

13

Axis Unit input / output control lines (PLC) connector.
Refer to Chapter 4 for detailed signal descriptions.

AXIS-I/O

12

Connector for the nutrunner (tool) motor (M).

MOTOR

11

Connector for the nutrunner (tool) encoder (ENC).

ENCODER

10

Connector for the tool torque transducer/preamplifier (PA).

SENSOR

9

Axis Unit enable / disable switch.

NORMAL / IN BYPASS

8

Display LED (red) that indicates when the Axis Unit is in the
Bypass mode. Spindle will not operate in this mode.

BYPASS

7

Display LED (red) that indicates some component of the
spindle (Axis Unit, nutrunner, etc.) is in an Abnormal state,
and the fastening cycle has been interrupted. A failed Cal
Check or Zero Check will also display as an ABNORMAL.

ABNORMAL

6

Display LED (green) that indicates the spindle has
completed an acceptable fastening, Zero Check, or Cal
Check.

ACCEPT

5

Display LED (orange) that indicates when the fastening
cycle is performing a reverse operation.

REV

4

Display LED (orange) that indicates when the fastening
cycle is performing the final steps.

FNL

3

Display LED (orange) that indicates when the fastening
cycle is performing the 1st step.

1ST

2

Display LED (orange) that indicates when the system is
performing a Cal Check or Zero Check.

CHECK

1

DESCRIPTION (REFERENCE FIGURE 3-2-4)

ITEM AS MARKED ON UNIT

AXIS UNIT CONTROLS AND INDICATORS

Chapter 3: System Description

User Console Version A3.53

Page 3-9

Advertising