2.4
Axis Controller Unit Specifications
200~230 VAC, 3-Phase, 50/60 Hz
AXIS UNIT INPUT POWER
100A
70A
70A
50A
50A
50A
AXIS UNIT IN-RUSH CURRENT
4A
2A
2A
1A
.625A
.625A
AXIS UNIT PEAK CURRENT
400W
200W
200W
100W
70W
60W
TOOL MOTOR RATING
MFA040
HA1NS
BXE020-
A912
MFA020
HA2NSA
MFA010
HA2NSA
BNE006-
A117
MFA006
HA2NSA
TOOL MOTOR MODEL
NUMBER
M4
W3
M3
M2
W1
M1
TOOL MOTOR TYPE
AXIS-210
AXIS-205
AXIS-203
AXIS UNIT TYPE
Example:
Tool (nutrunner) model DFT-401M2-S has an M2 motor type, and must be used
with a Type 203 Axis Unit.
NOTE:
The M1 and W1 motors are functionally identical units, and can be interchanged
without any special considerations. The same is true of the M3 and W3 motors.
CAUTION:
If the equipment is powered on and off repeatedly, the circuit breakers might
trip due to the in-rush current.
Chapter 2: Specifications