System Block Diagram Description

w The System construction provides control for up to 24 spindles through the use of a single ISA

Main Controller Unit.

w Communication between the ISA Main Controller Unit and up to 24 Axis Controller Units is

accomplished via a communication bus ribbon cable (MA/AA cable).

w Tool assemblies connect to their respective Axis Controller Units via a set of three homerun

cables: Motor, Encoder, and Sensor / Preamp (Transducer) cables.

w

A color Flat Panel LCD Screen (or optional VGA CRT)

and keypad provide the interface required

to monitor and adjust System operations.

w Discrete 24 VDC true low I/O on both the ISA Main Controller Unit and the Axis Controller Unit

provide direct communication with the PLC, as well as individual spindle control via the Axis
Controller Unit discrete I/O.

w Communication with additional devices is accomplished via:

P (1) RS232C input port

P (1) RS232C output port

P (1) RS422 port (option)

P (1) Centronics parallel port.

Chapter 3: System Description