FEC AFC1200 User Manual

Page 21

Advertising
background image

)(& ,QF

6.4

Reverse Functions

The AFC1200 System is capable of reverse operations using three different control methods.
There are three independent reverse presetting options to choose from when performing
these operations. The following list details the conditions under which each may be used:

P Manual switch located on the front of the Main Unit (NO. 1 REVERSE)

P PLC REVERSE input signal (NO. 1 REVERSE)

P Fastening Sequence program (NO. 1, 2 and 3 REVERSE)

CAUTION:

REV3 must not be used as a reject backout on a rundown sequence.
REV3 will perform a judgment that may result in an erroneous accept output.

NO.1 REVERSE

NO.1 REVERSE

NO.2 REVERSE

NO.3 REVERSE

TIME

TIME

TIME

NO.2 REVERSE

NO.3 REVERSE

[ ] RPM

[ ] REV

[ ] REV

[ ] REV

REVERSE ANGLE

[ ]

HIGH [ ]

LOW [ ]

REVERSE TORQUE

HIGH [ ]

LOW [ ]

REVERSE START TORQUE

[ ]

[ ] RPM

[ ] RPM

[ ] SEC

[ ] SEC

[ ] SEC

FIG. 6-4 Reverse Functions

Lower control limit for reverse torque monitoring. Set according to
the engineering specification

REVERSE TORQUE LOW

Upper control limit for reverse torque monitoring. Set according to
the engineering specification

REVERSE TORQUE HIGH

Lower control limit for reverse angle control. Set according to the
engineering specification

LOW (ANGLE)

Upper control limit for reverse angle control. Set according to the
engineering specification

HIGH (ANGLE)

Once REVERSE START TORQUE is reached, the System will back
out for this amount. Set to a value which will provide the proper
duration of backout according to the engineering specification

REVERSE ANGLE

Once this torque is reached, the System will back out for the amount
specified by Reverse angle. Set to a value which will provide the
proper duration of backout according to the engineering specification

REVERSE START TORQUE

The desired duration of reverse operations may be set in either
seconds or number of revolutions. Preset in conjunction with RPM to
attain the desired backout. NO. 1 REVERSE will back out for as long
as the manual reverse input is maintained

REVERSE TIME

The desired speed may be uniquely set for each of the three reverse
modes

RPM

RECOMMENDATION

FUNCTION

Chapter 6: Fastening Instructions

Page 6-21

Advertising