FEC AFC1200 User Manual

Page 7

Advertising
background image

)(& ,QF

Maximum allowable Final Step time

FINAL STEP (TIME)

Maximum allowable fastening cycle time

1ST STEP (TIME)

Engineered fastening specification for rotation
angle

FINAL ANGLE

30 ~ 50% of resultant torque for Hard joints
50 ~ 90% of resultant torque for Soft joints

SPEED CHANGE (TORQUE)

Engineered fastening specification at which Angle
Control begins

THRESHOLD 2 (TORQUE)

30 ~ 50% of FINAL ANGLE or resultant torque for
Hard joints
50 ~ 90% of FINAL ANGLE or resultant torque for
Soft joints

1ST TORQUE/ANGLE

RECOMMENDATION

FUNCTION

P Two-step fastening will be used primarily for joints that have a requirement to

synchronize with another spindle during the final stage of the rundown (connecting
rod, main bearing cap and any other multiple-spindle unit, for example).

P The System will fasten to the 1ST TORQUE/ANGLE during the specified 1ST

STEP time. Once either SPEED CHANGE TORQUE or 1ST TORQUE/ANGLE is
reached, the System will switch to the specified TORQUE SPEED (Section 6.3).
When all fasteners have reached 1ST TORQUE/ANGLE, the spindles will
synchronize and then rotate simultaneously the specified number of degrees from
THRESHOLD 2 TORQUE to FINAL ANGLE within the specified FINAL STEP time.

STD.

TORQUE

1ST STEP

FINAL

STEP

ANGLE

SPEED CHANGE

1st TORQUE

FIG. 6-1-2b Angle Control Functions for Two-Step Fastening

Chapter 6: Fastening Instructions

Page 6-7

Advertising