Chapter 8: Troubleshooting

Code A8_6 - SERVO AMPLIFIER ERROR / INPUT VOLTAGE ABNORMAL

The SAN controller servo power supply circuit has detected improper input voltage either above
or below the specified limits.

CAUSE:
1. The controller internal power supply has failed.
2. Source voltage is out of the limit (180-242 VAC) and/or the environment temperature is also

close to the limit.

3. One or more phases of input power are missing.

RECOVERY:
1. Replace the controller.
2. Provide additional cooling to the enclosure.
3. Verify and correct the source voltage as required (between 180-242 VAC 3 phase).

Code A8_9 - SERVO AMPLIFIER ERROR / OVER SPEED.

The resolver signal received at the SAN controller indicates an over speed condition.

CAUSE:
1. The resolver cable or resolver has failed.

RECOVERY:
1. Check resolver using method in 7.2.3.
2. Replace resolver cable with spare cable.
3. Replace tool assembly.

Code A8_10 - SERVO AMPLIFIER ERROR / OVER LOAD (I SQUARE T)

The duty cycle of the press application is too severe for this size of tool, or for the parameters
currently set up.

RECOVERY:
1. Reduce duty cycle - Increase tool “downtime or off time” and/or increase Press Speed and

Part Search Speed to reduce the amount of time running at high load/slow speed.

2. Increase the Press Speed Start Load or Press Speed Start Distance at which Part Search

Speed shifts to Press Speed.

3. If using Load Hold, try decreasing the hold time.
4. If the problem remains, a larger tool assembly may be required for this application. Please

contact FEC.

5. If this happens while performing a “Home Position Search”, verify that the brake is operating

correctly.

Code A8_11 - SERVO AMPLIFIER ERROR / RESOLVER SIGNAL ERROR.

The resolver signal received is not correct.

RECOVERY:
1. Check the cable and look for loose connectors or visible damages to the cable.
2. Replace with known good tool.