ELECTRICAL

voltage

phase

cycle

/

hz

amps

kW

cord

and

plug

208-240

(

agcy

)

1

60 28.8 6.0

no

cord

at 208

1

60

28.9

6.0

or

plug

at 240

1

60

22.2

5.3

230

(

agcy

)

1

50

21.3

4.9

no

cord

or

plug

The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National Electrical

Code and applicable local codes.
Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is easily

accessible in case of an emergency. Arcing will

occur when connecting or disconnecting the unit

unless all controls are in the “

off

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed by

a licensed electrician in accordance with applicable

local electrical codes.
With the voltage conversion switch in the 200-208V

(UPPER) position, the oven will function properly

with a source voltage of between 200 and 208.
With the voltage conversion switch in the 220-240V

(LOWER) position, the unit will function properly

with a source voltage of between 220 and 240.

NOTE:

ALL 208-240V units are shipped from the

factory with the voltage conversion switch

in the 220-240 position.

All 125V rated units will function properly with a

source voltage of between 100 and 125, 60 Hz.
The 125V rated units are provided with a cord

and plug [NEMA #5-20P]. Have a licensed

electrician install the proper outlet configuration as

required for the unit in accordance with applicable,

local electrical codes. This will assure a safe and

trouble-free installation.

Ensure that the voltage conversion switch position

and the available power source match.

230V:

To prevent an electrical shock hazard between

the appliance and other appliances or metal parts

in close vicinity, an equalization-bonding stud is

provided. An equalization bonding lead must be

connected to this stud and the other appliances /

metal parts to provide sufficient protection

against potential difference. The terminal is

marked with the following symbol.

NOTE:

230V appliances must be connected to

an electrical circuit that is protected by

an external GFCI outlet.

E L E C T R I C A L C O N N E C T I O N

I N S T A L L A T I O N

D A N G E R

ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

D A N G E R

ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.

Wire diagrams are located inside the bonnet of the unit .