Installation guide – Blagdon Pump Pulsation Dampeners User Manual
Page 6
![background image](/manuals/346936/6/background.png)
Models PD25M, PD40M, PD50M, PD80M
Page 4
Blagdon Pump
®
, IDEX Pump Technologies (Ireland) Ltd., A Unit of IDEX Corporation • R79, Shannon, Co Claire, IRELAND • Tel: +353 61 47933
www.blagdonpump.com
pdsm-rev0510
1
2
3
Pulsation Dampener
Filter/Regulator
Lubricator
Available from
Blagdon Pumps
1
2
3
INSTALLATION GUIDE
®
CAUTION
The air exhaust should be
piped to an area for safe
disposition of the product
being pumped, in the event
of a diaphragm failure.
Installation Guidelines
For best results, the factory recommends
installing the surge suppressor on the discharge
side of the pump. Though the more common
top-ported pump is shown here, this
recommendation also applies to bottom,
side and dual-ported diaphragm pumps.
The compressed air supply line to the surge
suppressor should connect before a filter/
regulator unit limited to inlet air of 125 PSI.
Flexible connections are strongly recommended.