Pulsation dampener model pd80m, Design level 2, Operating and maintenance manual – Blagdon Pump Pulsation Dampeners User Manual

Page 9: Warning, Caution, Hazard warning, Warning caution

Advertising
background image

Model PD80M Page 7

Blagdon Pump

®

, IDEX Pump Technologies (Ireland) Ltd., A Unit of IDEX Corporation • R79, Shannon, Co Claire, IRELAND • Tel: +353 61 47933

www.blagdonpump.com

pd80mdl2sm-rev0510

O

perating and Maintenance Instructions

The Blagdon Pump PULSATION DAMPENER is a completely automatic

diaphragm-fitted pulsation dampener to reduce the flow and pressure pulsations

in a pumping system characteristic of reciprocating type pumps.
Principle of Operation: The PULSATION DAMPENER uses a flexible diaphragm

to separate a liquid chamber from compressed air chambers. A rod connected

to the center of one diaphragm activates the air inlet and exhaust valves, which

automatically admits or exhausts air in the air chambers. This maintains the

diaphragms in mid-range of stroke for maximum pulsation dampening.
Installation: Locate the PULSATION DAMPENER in discharge piping as close as

possible to the pump. Measures must be taken to support the weight of the unit.

Do not rely on piping connection for support of the unit. The unit will operate in

any position. Connect the air inlet connection to an air supply line having the

same air pressure as that at the air inlet connection to the pump. Do not exceed

8.6 Bar/125 PSI.
Service Instructions: When service is required, it is important to MAKE

CERTAIN THAT INLET AIR PRESSURE AND LIQUID SYSTEM PRESSURES

ARE VENTED. Before maintenance or repair, shut off the compressed air line,

bleed the pressure, and disconnect the air line from the pump. The discharge

line may be pressurized and must be bled of its pressure. When used for toxic or

aggressive fluids, the unit should always be flushed clean prior to disassembly.

The diaphragms are serviced by simply removing twelve hex nuts and removing

the center spool casting.

When PTFE diaphragms are used in conjunction with the elastomeric diaphragms

they are placed over the “wetted” sides of each elastomeric diaphragm. Inlet and

exhaust air valves are located externally for easy access and service.
Warranty: This unit is guaranteed for a period of five years against defective

material and workmanship.

OPERATING AND MAINTENANCE MANUAL

Pulsation Dampener Model PD80M

Design Level 2

Before doing any

m a i n t e n a n c e o n t h e

pulsation dampener, be

certain all pressure is

completely vented from the

pump, suction, discharge, piping, and all other

openings and connections. Be certain the air

supply is locked out or made non‑operational,

so that it cannot be started while work is being

done on the pump. Be certain that approved

eye protection and protective clothing are worn

all times in the vicinity of the pump. Failure to

follow these recommendations may result in

serious injury or death.

WARNING

Read these safety warnings

and instructions in this

manual completely, before

installation and start‑up of

the pulsation dampener. It

is the responsibility of the purchaser to retain

this manual for reference. Failure to comply

with the recommendations stated in this manual

will damage the pulsation dampener, and void

factory warranty.

Before surge suppressor

operation, inspect all

gasketed fasteners for

looseness caused by

gasket creep. Re‑torque

loose fasteners to prevent leakage. Follow

recommended torques stated in this manual.

CAUTION

POSSIBLE EXPLOSION HAZARD can result if

1, 1, 1, ‑Trichloroethance, Methylene Chloride

or other Halogenated Hydrocarbon solvents

are used in pressurized fluid systems having

Aluminum or Galvanized wetted parts. Death,

serious bodily injury and/or property damage

could result. Consult with the factory if you

have questions concerning Halogenated

Hydrocarbon solvents.

HAZARD WARNING

Take action to prevent static

sparking. Fire or explosion

can result, especially

when handling flammable

liquids. The pump, piping,

valves, containers or other

miscellaneous equipment must be grounded.

WARNING

CAUTION

Advertising