CALIBRATION INSTRUCTIONS:

Loosen set-screw on Calibration

Bracket

Set adjustment dial to “0” Closed

Activate switch to extend to the

“STOP”

Slide Calibration Bracket to

ensure shut-off is closed

Calibration is now complete

To Calculate RATE SETTINGS:

Determine how much material is

to be applied per 1,000 sq./ft.

Measure off a distance of 50 feet, preferably on a paved surface such as a parking lot.

Weigh out enough of the material to be applied to fill the hopper at least half full. Record the weight for

future use.

With the unit mounted on the vehicle and the hopper at least half full of the material

to be spread, position the vehicle far enough before the beginning of the 50 foot test

area so that the vehicle will achieve the desired speed before you reach the starting

line.

Select the Setting Rate position that you feel would be an appropriate setting on the

ECM Module 1-11. IMPORTANT - only make Rate Adjustments with the shut-off in

the CLOSED POSITION

Start the vehicle in motion and as you cross the starting line (of the 50 feet) move the

rate lever to the open position against the stop. Take care to be aware of what is going

on around you maintaining control of the vehicle.

Continue from the starting line with the unit spreading the material. As you cross the

finish line move the rate lever to the closed position.

Stop the vehicle and note the width of the spread path that was just completed.

Return to the start point and empty the remaining material from the hopper into your weighing container

and re-weigh.

OPERATING INSTRUCTIONS:

Before filling hopper, become familiar with the operation of this spreader. (Practice the following steps)

Turn the motor switch to the “ON” POSITION, so that the impeller is turning before going on to the next

step.

While driving forward turn the ECM Control switch (wide top switch) to the “ON” POSITION, this opens the

shut off plate on the spreader.

To stop the flow of material, turn the ECM Control switch to the “OFF” POSITION, then turn the motor off

when finished.

When finished empty any remaining material from hopper.

Thoroughly wash spreader and allow to dry before storing. Lubricate all moving parts with a graphite or

silicon spray.

Step 3

Step 4

EarthWay

®

To Calibrate loosen

set screw

slide Calibration

Bracket

Install Calibration Bracket to ECM

shaft by sliding the Calibration Bracket

on to the ECM shaft.

M80 Side

M40 Side

To install Calibration Bracket you must

determine which leg corresponds to your

spreader. Short for M40, and long

for M80

Install Control Rod on to Shut-Off from

the top down and secure with small Hair Pin

Clip. Then attach the other end of the Control

Rod to the Calibration Bracket from the

bottom up.

Tip: You may need to retract ECM to fully

closed “0” to aid in installing the Calibration

Bracket

SLID

E

Motor

Connection

C L

O S

E D O P E N

Turn

ECM Rate Adjustment

1 1

1 0

9

8 7

6 5 4 3 2

1

0