E.
Installation Procedure
1.
Select a location which is level and will fully support the weight of the platform plus
a full capacity load.
2.
Remove the top of the crate and all packing/banding material.
3.
Screw the two (2) eyebolts into the threaded adapters in the platform top. Use a
forklift or other lifting means along with chains, cables, or nylon straps to remove
the scale from the crate bottom.
4.
Set the scale so the interface cable exits in a direction where it can be protected.
If possible, use a cable protector to reduce trip hazards and protect the interface
cable from being damaged.
5.
Wire the scale interface cable to the proper type indicator using the following
platform wiring/ color code:
Cable Wire Color
Function
Analog Instrument
Black
(-) Excitation
(-) Excitation
Green
(+) Excitation
(+) Excitation
Yellow
Shield
Shield
White
(+) Signal
(+) Signal
Red
(-) Signal
(-) Signal
10/06
7
50783 Issue 2
~Caution~
Failure to use the proper lifting tools may result in personal injury.