Outputs, Pc2255, Power requirements – Fairbanks 1155 SERIES Portable Utility SCALE WITH THE FB2255 User Manual
Page 11: Out of range warnings, Environment, Specifications, continued

Section 1: General Information
02/13
11
51315 Rev. 1
1.4. SPECIFICATIONS, CONTINUED
1.4.5.
OUTPUTS
PORT 1
Bidirectional Serial Port. Settings include OFF, RS232, and
RS485. RS232 has 30+ updates a second
PORT 2
Port 2 is used to interface to the PC2255 program,
OR,
Provide 20 mA passive, RS 232, or RS 485.
1.4.6.
PC2255
• Computer software utility program is available for download using the Fairbanks Intranet.
• PC2255 is required for setting certain aspects of programming, such as custom Units and custom
ticket formatting.
1.4.7.
POWER REQUIREMENTS
• 117 volts AC +/- 10 %
• 220 volts AC +/- 10 %
• < 0.2 volts AC between Neutral and Ground
• 1.5 watts maximum
• The FB2255 is designed to operate from 80 to 260 volts AC, 50 to 60 Hertz
1.4.8.
OUT OF RANGE WARNINGS
HiCAP
Scale input is over capacity
- - - - - - -
Displayed weight exceeds 6 digits
1.4.9.
ENVIRONMENT
Temperature
-10ºC to + 40ºC (+14ºF to + 104ºF)
Storage Temp.
-40ºC to + 60ºC (-40ºF to + 140ºF)