B. configure output, continued – Fairbanks FB6002 INSTRUMENTATION User Manual

Page 78

Advertising
background image

Appendix I: Data Output

01/13

78

51293 Rev. 2

B. CONFIGURE OUTPUT, CONTINUED

CARDINAL 738 CONTINUOUS SCOREBOARD DATA FORMAT

<CR><P><WWWWWW.><M><SP><U><SP><G><SP><SP><ETX>

NOTES:

1. W = Displayed weight

P = Polarity

+ = Positive weight

- = Negative weight

U = Units

lb = pounds

kg = kilograms

M = Motion or O = Overload

G = Gross; N = Net

SP = Space

2. Leading zeros are not suppressed.

WEIGHTRONIX DATA FORMAT

< ><M><WWWWWW>< ><U><CR><LF>

NOTES:

1. < > = Space

M = Mode

G =Gross

T=Tare

N=Net

W = Displayed weight

U = Units

m = Motion

o = Overload

2. Leading zeros are suppressed.