The weigh rail, its approaches, the load cells, and their housing are

arranged in a configuration that requires no space above the customer's

normal supporting structure. All components of the Unirail are

assembled as one complete calibrated unit ready for installation into the

existing monorail line. Install the Unirail at the approach rails by direct

attachment to the rail hangers. The scale should be installed level in

both directions in the horizontal plane. If level condition along the rail

cannot be obtained, out of level must not exceed 0.6 degrees, for 0.5

feet on the length of the weigh rail. There is no welding required to

install the scale. If any welding is required on any adjacent structure,

perform the welding prior to scale installation. If welding is required after

installation, the entire scale assembly, live and adjacent dead rails,

should be physically removed prior to welding to avoid possible damage

to the load cells.

W

W

ARNING:

ARNING:

DO NOT weld on the scale structure or damage to the load cells

DO NOT weld on the scale structure or damage to the load cells

may occur

may occur

.

.

Note:

Use cast or fabricated steel hangers to support the scale structure.

Do not use light gauge (cold formed) steel hangers.

50019

10

03/12 - Rev. 8

F.

Installation

Instructions

Overview

Warning