The weigh rail should remain in the center of its fixed approaches, and

free to move up and down very slightly on its load cell mounts. The

weigh rail must remain free and unobstructed for proper performance.

Periodic examination and cleaning any debris from its gaps should be

performed regularly. Do not lubricate, grease, or oil any part of the

Unirail.

Loadcells & Weighrail:

1. Load cells for the Unirail are provided in matched pairs, and are

always replaced as a set. Electrical connections are intended to be

individually soldered and insulated, and re-installed in the splice tube.

Note wiring connections before disconnecting them, and removing the

weighrail and loadcells.

2. Mount the replacement load cells to the support bar with existing 1/2-

20 cap screws. Tighten finger tight.

3. Mount the weighrail to the cells using the load cell mounting tool pn

95272. The tool is effectively a threaded stud having a shaft diameter

equal to the hole in the load cell. It centers the rail for optimum

clearence. Equally space the weighrail between the approach rails,

then tighten the load cell support screws.

4. Torque the cell support screws to approximately 75 ft lbs.

5. Remove the Unirail load cell fixure screws supporting the weighrail to

the load cells, and replace them with the special studs. Use the stud

locking compound. Remove the weighrail and torque the studs to

approximately 75 ft lbs.