A. Maintenance Inspections

• Ensure that the system is maintaining proper ground connections

• Check module to module bolts for tightness

• Check that the frame has not shifted, that all bolts are secure

• Check for 'give' or washout under any temporary pier structures

• Check load cells for a level condition

• Examine load cell cables and module interconnect cables for problems

• Ensure that the SSCs and the PPSs covers are secure

B. Load cell Replacement

• Remove power from the system at the instrument

• Jack the scale at the 'bad' load cell location

• Remove the old load cell.

• Apply a small amount of grease to the load cell buttons (top and bottom), then install

the new load cell.

• Gently lower scale assembly ensuring proper placement of load cell.

• Loosen the gland nut, unwire the defective load cell from the SSC, record the wire

color code

• Wire the new cell into SSC, tighten the gland nut around the cable.

• Close the SSC and tighten all screws to 10-12 in.-lbs..

• Reapply power to the instrument

• Check operation, calibrate as necessary

C. Smart Sectional Controller Replacement

• Remove power from the system at the instrument

• Remove cover, disconnect all wiring, noting colors and terminal locations

• Remove screws securing PC board

• Carefully remove prom and insert in new PC board, note DIP switch settings

• Set DIP switches for proper address on new PC board

• Install PCB and secure with all screws

• Connect all wires

• Secure cover with all screws torqued to 10-12 in.-lbs.

• Tighten all gland nuts to secure.

D. Pit Power Supply Replacement

• Remove power from the system at the instrument

• Remove PPS cover and disconnect all wiring

• Remove screws securing power board

• Remove old PCB, secure ground wire to new PCB

• Remake all connections, install the new PCB and secure all screws

• Secure cover with all screws torqued to 10-12 in.-lbs..

• Tighten all gland nuts to secure.