50767

7

01/08 Rev. 2

JACKING SCREW

JACKING SCREW

GROUNDING CABLE

GROUNDING CABLE

TOP PLATE

TOP PLATE

BASE PLATE

BASE PLATE

5/8"-11 UNC (2x) (10K )

5/8"-11 UNC (2x) (10K )

1/2"-13 UNC (2x) (5K & under)

1/2"-13 UNC (2x) (5K & under)

(Bolts not provided)

3/8"-16 UNC (4x) (5K & under)

3/8"-16 UNC (4x) (5K & under)

UPLIFT PROTECTION

UPLIFT PROTECTION

1/2"-13 UNC (4x) (10K )

1/2"-13 UNC (4x) (10K )

(Bolts not provided)

C

D

E

F

H

I

J

K

L

M

N

G

A

B

(Optional)

50767-1

DIMENSIONS (in inches) Corresponds to drawing above.

Capacity

A B C D E F G H I J K L M N

5000 lb and under

3.54 0.59 1.38 6.30 5.12 1.57 0.98 6.50 3.15 0.47(4x) 0.51 2.75 1.97 3.94

10,000 lbs

5.12 0.98 1.97 7.87 6.69 1.97 1.38 8.27 4.13 0.57(4x) 0.63 3.94 2.76 4.72

Note:

a. The load cell mounting bolts for the 500 - 2.5k assemblies must be torqued to 66 ft-lbs.

b. The load cell mounting bolts for the 5k assemblies must be torqued to 88 ft-lbs.

c. The load cell mounting bolts for the 10k assemblies must be torqued to 295 ft-lbs.