Omnicell placement, Follow these guidelines for installing omnicell, Load cells – Fairbanks 9102 FB Omnicell User Manual

Page 13

Advertising
background image

Section 2: Installation

10/07

13

51175 Rev. 3

Omnicell Placement

Follow these guidelines for installing
Omnicell

®

Load Cells.

1. The loading points of the modules should be as

far from one another as the structure allows.

2. When installing the square and rectangle

Omnicell units, line up the Base Plates of the
Load Cells with each other, and align them
evenly from the end and the sides of the units.

3. When installing six Load Cells (Figure 5), be

extremely careful

to position the center

Omnicells

®

to exactly the same height as the

outer Omnicells

®

.

Advertising