INTRODUCTION
The Little Cooler is a closed-loop cooling system designed to work with an FTI distillation
system. Use of the Little Cooler can save money and conserve the environment by eliminating
the continuous use of a clean water supply. Further, this air-cooled system uses no ozone-
depleting gasses to perform its job. Quality engineered and manufactured, the Little Cooler
requires minimal operator involvement and maintenance and can provide years of trouble-free
service. The Little Cooler is compatible with all of FTI’s electrically heated LS-Series solvent
distillation systems.
SAFETY PRECAUTIONS
WARNING:
READ THIS MANUAL COMPLETELY BEFORE INSTALLING AND OPERATING THIS
UNIT. FAILURE TO FOLLOW THESE PRECAUTIONS CAN RESULT IN SERIOUS
INJURY OR DEATH.
The Little Cooler is non-explosion proof and must be installed outside the hazardous area.
Do not use the Little Cooler for processing solvents with boiling points below 150F.
Ambient temperature of installation area must not exceed 100F.
A qualified electrician should perform electrical wiring.
Any electrical wiring or components connected to the Little Cooler that enter a hazardous
area must conform to the explosion proof standards for that hazardous area.
Store and keep all flammables and combustibles a safe distance from the unit. A minimum
of 20 feet is required.
Wear proper eye and skin protection when installing, operating, or maintaining this
equipment.