The Little Cooler is a closed-loop cooling system designed to work with an FTI distillation
system. Use of the Little Cooler can save money and conserve the environment by eliminating
the continuous use of a clean water supply. Further, this air-cooled system uses no ozone-
depleting gasses to perform its job. Quality engineered and manufactured, the Little Cooler
requires minimal operator involvement and maintenance and can provide years of trouble-free
service. The Little Cooler is compatible with all of FTI’s electrically heated LS-Series solvent
distillation systems.


SAFETY PRECAUTIONS

WARNING:

READ THIS MANUAL COMPLETELY BEFORE INSTALLING AND OPERATING THIS
UNIT. FAILURE TO FOLLOW THESE PRECAUTIONS CAN RESULT IN SERIOUS
INJURY OR DEATH.


 The Little Cooler is non-explosion proof and must be installed outside the hazardous area.

 Do not use the Little Cooler for processing solvents with boiling points below 150F.

 Ambient temperature of installation area must not exceed 100F.

 A qualified electrician should perform electrical wiring.

 Any electrical wiring or components connected to the Little Cooler that enter a hazardous

area must conform to the explosion proof standards for that hazardous area.


 Store and keep all flammables and combustibles a safe distance from the unit. A minimum

of 20 feet is required.


 Wear proper eye and skin protection when installing, operating, or maintaining this

equipment.