ELECTRICAL CONNECTIONS


General electrical instructions:
 The Little Cooler requires a switched 230-volt, 1 phase, 60 Hz, 20 amp electrical service

with separate ground and circuit breaker.

 A qualified electrician should perform all electrical wiring.
 When installing outdoors, use only weather-tight electrical components.
 Run the electrical supply from your circuit breaker to your switch, then to the Little Cooler.
 Bring your 3-wire supply to the inside of the Little Cooler’s junction box. Connect your L1

supply to the two black wires, your L2 supply to the two red wires (use the wire nuts
provided) and secure your ground to the junction box. Verify that L1 and L2 are secured
and not shorting to ground.


NOTE: If using the Little Cooler with models LS-15IIE or LS-55IIE, refer to the “Electrical
Connections for Models LS-15IIE and LS-55IIE” section of this manual for additional
instructions if automated start/stop operation is desired.











JUNCTION

BOX

ATTACH YOUR

CONDUIT HERE