LEVEL CONTROL BOARD REPLACEMENT:


Disconnect electrical power to the BE unit before replacing

the Level Control Board.


When replacing a Level Control Board take care to install the proper wires onto the proper terminals. If any
of the wire’s push-on connectors seem loose or corroded, replace the connectors as well. Two “Series” of
Level Control Boards with two different voltage ratings have been used:

 For units E91 to E92, the replacement Level Control Board and is a 120-volt version and is identical to

the original part (Series 16). No wiring changes or modifications are required.


 For units F92 to I93, the replacement Level Control Board is a 240-volt version and will be slightly

different (Series 16 to Series 26). Minor wiring changes are required—see diagram below.


 For units J93 to present, the replacement Level Control Board is a 240-volt version and is identical to the

original part (Series 26). No wiring changes or modifications are required.

SERIES 16

L1

L2

H

L

NC

COM

NO

W

SERIES 26

L1

L2

NC

COM

NO

W

L
L

C
O

G

RESET

WIRE L2

WIRE L1

WIRE #21

WIRE #21

WIRE #22

WIRE #10

WIRE #10

WIRE #26

WIRE #26

SERIES 16

L1

L2

G

H

L

NC

COM

NO

W

WIRE #22

G

WIRE L1

WIRE L1

WIRE L2

WIRE N

WIRE #24

WIRE #22

WIRE #21

WIRE N

LEVEL CONTROL BOARD - 120 VOLT

LEVEL CONTROL BOARD - 240 VOLT

SERIES 16

SERIES 16

SERIES 26

CAUTION: