Specifications – KISAE SC 1220LD Solar Charge Controller User Manual

Page 6

Advertising
background image

Check connection polarity. Reverse polarity on any terminals will damage
unit and is not covered by warranty.

Verify the DC load consumption. The power consumed by the DC load
should be less than the PV panel generates.

8. Specifications

SC 1210

SC1210LD

SC1220LD

Battery Voltage:

12 VDC

PV open circuit voltage (max):

26 VDC

Charge current (max):

10 A

10 A

20 A

Load current (max):

10 A

10 A

20 A

Surge Current (max)

35A for 1 min

35A for 1 min 40A for 1 min

Operational current:

< 10 mA

<10 mA

<15 mA

Regulated battery voltage

Sealed type:

14.2 VDC

Flooded type:

14.6 VDC

Load disconnect voltage:

N/A

< 11.5 VDC

< 11.5 VDC

Load re-connect voltage:

N/A

12.6 VDC

12.6 VDC

Recommended wire size:

# 12 AWG

# 12 AWG

# 10 AWG

Operating temperature

- 40 C to 60 C

Dimensions (L x W x H)

4.1 x 4.1 x 1.3 in

Weight:

0.28 kg

0.32 kg

0.35kg

Advertising