Ransburg – Ransburg RCS 2 Ratio Control System User Manual
Page 27

independent of each other. Note that the horn must
be enabled on the CONFIG SYSTEM screen or
the horn will not sound for gun faults regardless
of whether or not they are configured to do so on
the CONFIG GUN screens.
System Pulse
Type of Output: System
Type of Signal: Pulsing
This output pulses at approximately a 0.5 hertz rate
as long as the processor on the interface board
does not detect any on-board firmware problems.
Users may wish to use this signal to detect when
the RCS-2 controller is powered up and running.
System User Link
Type of Output: System
Type of Signal: Maintained
This output is energized as long as the Ethernet
link between the user interface PC and the inter-
face card is functioning.
NOTES
RCS-2 User Manual - Installation
24
LN-9407-00.2
Ransburg