Ransburg, Appendix k: error codes (continued), Rcs-2 user manual - appendix – Ransburg RCS 2 Ratio Control System User Manual
Page 72

APPENDIX K: ERROR CODES (Continued)
Error
Name
Description
Explanation and/or Possible Causes
Pressure
Pot Empty
Inlet
Pressure
Loss
Outlet
Pressure
Loss
Analog
Remote
Loss
Ratio
Out of
Tolerance
Motor
Amplifier
Fault
Analog
Feather
Loss
Analog
Spare
Loss
Foldback
Pressure
Reached
The system has determined the
pressure pot is empty for the
respective channel
The electrical current from the
Pump Inlet
Pressure Sensor is less than 1
milliamp
The electrical current from the
Pump Outlet Pressure sensor is
less than 1 milliamp
The electrical current from the
Remote Analog Setpoint source
is less than 1 milliamp
The difference between the de-
sired ratio and the actual ratio,
expressed as a percentage error,
exceeds the Flow Rate/Ratio Tol-
erance Percentage value speci-
fied in the Gun Configuration.
The motor amplifier has detected
a fault condition.
The electrical current from the
Feather pressure sensor is less
than 1 milliamp
The electrical current from the
Spare Analog Input sensor is
less than 1 milliamp
The Pump Outlet pressure has
exceeded the Foldback Pressure
value specified in the System
Configuration
1. The value entered for the pressure pot
Capacity in the Job Configuration is
Incorrect.
2. The operator neglected to reset the
Pressure Pot.
Capacity when it was last filled.
3. Pressure Pot is empty.
1. Electrical connection problems.
2. Failure of Pump Inlet Pressure sensor.
1. Electrical connection problems.
2. Failure of Pump Outlet Pressure sensor.
1. Electrical connection problems.
2. The Remote Analog Setpoint source is
configured for voltage instead of current
loop.
1. Loss of feedback signal from motor
amplifier or flow meter.
2. Incorrect Calibration Factor in Channel
Configuration.
3. One or both channel is unable to deliver the
correct flow rate due to restriction in the
fluid line, lack of material.
1. Reference the motor amplifier diagnostics
to determine the cause of the fault.
1. Electrical connection problems.
2. Failure of Feather Pressure sensor.
1. Electrical connection problems.
2. Failure of Spare Analog input sensor.
1. This error is normal when operating in Fast
Fill or Channel Fill mode.
2. For Automatic guns, restriction in the fluid
line.
3. For Automatic guns, failure of applicator
trigger valve.
Source
Channel
Card
Channel
Card
Channel
Card
Channel
Card
Channel
Card
Channel
Card
Channel
Card
Channel
Card
Channel
Card