Ransburg – Ransburg Evolver MicroPak Controller A10406 User Manual
Page 10

MICROPAK A10406 ATEX
PRODUCT MARKING DEFINITIONS
Ex Certificate Number: Sira 05 ATEX 5 127 X
Sira = Notified Body performing EC-type
examination
05 = Year of certification
ATEX = Reference to ATEX Directive
5 = Protection Concept Code (code 5 is titled
Encapsulation)
127 = Document serial number
X = Special conditions for safe use apply
Special conditions for safe use: The Evolver 79190,
Series Automatic Atomizers shall only be used
with associated MicroPak A10406 or LECU5004-31
Power Supplies.
Product Marking
II 2 G
Ex = Specific marking of explosive protection
II = Equipment Group hazardous area charac-
teristics
2 = Equipment Category
G = Type of explosive atmosphere (gases, vapors,
or mists)
EEx 0.24mJ = The MicroPak A10406 Power
Supply is suitable for use in automatic spraying
installations complying with EN 50176 as they
are a Type A class with a discharge energy limit
of 0.24mJ.
NOTES
Evolver MicroPak Controller - Atex
Ransburg
7
LN-9622-00.5