Ransburg, Evolver micropak controller - maintenance – Ransburg Evolver MicroPak Controller A10406 User Manual
Page 28

Table 2. Ohmeter Measurements in Ohms from MicroPak Connector
J3 through the Low Voltage Cable to the HP404 Cascade.
Figure 9: Controller Top View
Signal
IFB
Vct
Vct
DrB
DrA
SigGnd
kVFB
PLFB
VctRet
From Wire 2 (white) 3 (red) 4 (black) 5 (green) 6 (blue) 9 (grn/yel) 10 (gray) 11 (orange) 16 (bare)
To Wire
2 (white)
XX
open ckt. open ckt. open ckt. open ckt. 19K - 21K 400K-600K 0 - 3
open ckt.
3 (red)
XX
0 - 3
0 - 3
0 - 3
open ckt. open ckt. open ckt.
open ckt.*
4 (black)
XX
0 - 3
0 - 3
open ckt. open ckt. open ckt.
open ckt.*
5 (green)
XX
0 - 3
open ckt. open ckt. open ckt.
open ckt.*
6 (blue)
XX
open ckt. open ckt. open ckt.
open ckt.*
9 (grn/yel)
XX
400K-600K 19K - 21K open ckt.
10 (gray)
XX
400K-600K open ckt.
11 (orange)
XX
open ckt.
16 (bare)
XX
* - Meter reading may vary in the megohms range due to capacitance across pins.
Evolver MicroPak Controller - Maintenance
Ransburg
25
LN-9622-00.5