POWER SUPPLY

CONNECTIONS

Route the control cable from the power supply

tank through the connector opening labeled HV

POWER SUPPLY at the top right of the control

panel and connect to TB4 (see Figure 6 for TB4

location) of the Mother Board printed circuit as-

sembly as detailed in Table 1.

It may be necessary to remove the cable grommet

to fit the control cable through the opening. If so,

slide the grommet hardware onto the control cable

in the order shown in Figure 6 before pulling the

cable through the connector housing.

Tighten the cable grommet ensuring the grommet

spring makes 360° contact with the exposed braid

of the control cable fro maximum noise immunity.

INTERLOCK

CONNECTIONS

Interlock terminals are provided for external fans,

conveyors, etc. Section 9-3.5 of NFPA- 33 requires

that automatic electrostatic equipment be inter-

locked with the exhaust air and conveyor. These

terminals are factory jumpered for test purposes

and identified by orange wire. The corresponding

factory installed jumper must be removed when

installing the desired interlock.

Refer to system installation drawings, the sche-

matic in Figure 5, and the electrical system

connections shown in Table 2 to determine the

appropriate exhaust air and conveyor interlocks

for your system.

All electrical interlocks are externally activated

by dry contact closure to the interlock terminals.

The dry contacts of the external interlock device

should have a contact resistance of no more than

1000 ohms and a minimum current rating of 2

Amps. The combined series contact resistance

should not exceed 3000 ohms if multiple devices

are used in series.

Route the interlock wiring through the connector

opening labeled INTERLOCK I/O on the bottom

of the cabinet and make the appropriate connec-

tions as described above. Since the interlock

wiring will be carrying 120 volts AC it should be

run in con-duit.

Figure 6: Inside View of Control Panel

>

The high voltage ON signal supplied

across terminals TB2 #3 to TB2 #5 or TB6

#3 to TB6 #5 MUST be a momentary con-

tact closure and not a maintained closure.

The overload circuit is inhibited as long

as the high voltage ON signal is supplied

and does not time-out until the signal is

removed. Therefore, if the HV ON contacts

remain closed, the power supply will

not

overload.