Ransburg – Ransburg Voltage Master 2 78789_LEPS5001 User Manual
Page 22

TB2-3 to TB2-5
TB2-8, TB2-8A, TB2-9, TB2-10
TB2-12, TB2-13, TB2-14
TB2-15
TB2-20
TB3-58
TB3-59
TB3-60
TB3-63
TB3-64
TB3-65
TABLE 2 - ELECTRICAL SYSTEM CONNECTIONS
External HV ON (PLC or Panel Switch)
External HV OFF/RESET (PLC or Panel Switch)
External System Interlocks (Exhaust Air, Conveyor, Reciprocator,
etc.)
External Alarm
DC Pump Control Output
kV Setpoint IN (0-10 VDC = 0-100 kV)
kV Setpoint IN (4-20 ma = 0-100 kV)
Actual kV OUT (0-10 VDC = 0-100 kV)
OL Setpoint IN (0-10 VDC or 4-20 ma = 0-1500 µa)
Actual Current OUT (0-10 VDC or 4-20 ma = 0-2000 µa)
Actual kV OUT (4-20 ma = 0-100 kV)
Description
Terminal Number
White
Black
Black
Red
Bare
TABLE 1 - POWER SUPPLY CONNECTIONS
Wire #
1
17
31
34
Shield
Color
TB4-1
TB4-17
TB4-31
TB4-34
TB4-GND
To Control Panel
PS1
PS2
PS3
SOL1
TABLE 3 - PNEUMATIC SYSTEM CONNECTIONS
External HV ON
External HV OFF/RESET
External Interlock
HV ON Output (Normally used for Air Logic Station HV ON indicator)
Description
Terminal Number
Voltage Master 2 - Installation
18
Ransburg
CP-02-02.6