Installation, Inst, Loca – Ransburg 9040 Classic Power Supply _NO2 Gun 76657-14, -142 User Manual
Page 12: Loca location tion tion tion tion, Input

CP-97-03.6
9040 Classic for the No. 2 Process Handgun - Installation
8
8
8
8
8
INST
INST
INST
INST
INSTALLA
ALLA
ALLA
ALLA
ALLATION
TION
TION
TION
TION
!
DO NOT
DO NOT
DO NOT
DO NOT
DO NOT locate the power supply near
or adjacent to heat producing equipment
such as ovens, high wattage lamps, etc.
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
!!!!!
!
The 9040 Classic Power Supply MUST
MUST
MUST
MUST
MUST
be located outside the hazardous area.
(See
National Fire Protection Association
Bulletin No. 33; the Occupational Safety
and Health Act of 1970, sections 1910.106
and 1910.107 and Ransburg Bulletin IL-
247,
Operating Your Electrostatic Coating
System Safely.)
!
The user MUST
MUST
MUST
MUST
MUST read and be familiar
with the SAFETY and SAFETY PRECAU-
TIONS SECTIONS of this manual.
!
This manual MUST
MUST
MUST
MUST
MUST be read and thor-
oughly understood by ALL
ALL
ALL
ALL
ALL personnel who
operate, clean or maintain this equipment!
Special care should be taken to ensure that
the warnings and requirements for operat-
ing and servicing safely are followed. The
user should be aware of and adhere to ALL
ALL
ALL
ALL
ALL
local building and fire codes and ordinances
as well as NFPA Standard 33 and The
Occupational Safety and Health Act of
1970 (OSHA) prior to installing, operating
and/or servicing this equipment.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
!
As each installation is unique, this in-
formation is intended to provide general in-
stallation information for the 9040 Classic
Power Supply. Consult your authorized
Ransburg distributor for specific directions
pertaining to the installation of your equip-
ment.
N O T E
N O T E
N O T E
N O T E
N O T E
LOCA
LOCA
LOCA
LOCA
LOCATION
TION
TION
TION
TION
Install the 9040 Classic Power Supply in an
area outside the hazardous location, where it
will be protected from the possibility of environ-
mental intrusion, such as dust or moisture, and
ambient temperatures do not exceed 120
o
F, but
as close to the applicator as possible to mini-
mize the length of the high voltage cable. The
Power Supply may be free standing on any flat
surface or wall mounted by rotating the wall
mount brackets (supplied) as shown in Figure 3.
In either case, the power supply MUST be
mounted in an upright position. DO NOT
DO NOT
DO NOT
DO NOT
DO NOT lay
the power supply on its side or back.
INPUT
INPUT
INPUT
INPUT
INPUT VOL
VOL
VOL
VOL
VOLT
T
T
T
TAGE
AGE
AGE
AGE
AGE
SELECTION
SELECTION
SELECTION
SELECTION
SELECTION
The 9040 Classic Power Supply accepts uni-
versal input voltage between 90 and 264 VAC.
There is no need to change any switch settings
when changing input from 115 to 230 VAC or
from 230 to 115 VAC.
!
9040 units shipped from the factory for
115 VAC input will have a 72771-06, 1 amp
front panel fuse installed. While 9040 units
shipped from the factory for 230 VAC input
will have a 72771-01, 0.5 amp front panel
fuse installed. If the other input is required,
it is recommended that the fuse be
changed in order to keep the same level of
protection. Both fuses are shipped with
9040 power supplies.
N O T E
N O T E
N O T E
N O T E
N O T E
Figure 3: Wall Mount Brackets
Figure 3: Wall Mount Brackets
Figure 3: Wall Mount Brackets
Figure 3: Wall Mount Brackets
Figure 3: Wall Mount Brackets