Ransburg 9040 Classic Power Supply _NO2 Gun 76657-14, -142 User Manual

Page 25

Advertising
background image

CP-97-03.6

4.

Press new switch (see "Parts Identifica-
tion" section of this manual for part num-
bers) into panel opening with terminals
1A and 2A to the bottom of the cabinet.

5.

Reconnect the four quick connect termi-
nals to the new switch as follows:

6.

Secure cabinet door and plug power
supply back in.

AC Line Cord

AC Line Cord

AC Line Cord

AC Line Cord

AC Line Cord

1.

Ensure power supply is unplugged from
AC outlet and open the cabinet door.

1SW-1
1SW-2

1SW-1A
1SW-2A

1FU-2

1TB-N

1TB-S1
1TB-S2

T o

T o

T o

T o

T o

From

From

From

From

From

2.

Using a screwdriver, disconnect dam-
aged line cord from 1TB-L1, 1TB-N, and
1TB-GROUND.

3.

Loosen the line cord grommet on side
panel and pull damaged cord out.

4.

Insert new line cord (see "Parts Identifi-
cation" section of this manual for part
numbers) through grommet and connect
to 1TB as follows:

!

ALWAYS

ALWAYS

ALWAYS

ALWAYS

ALWAYS double check that the power

supply is unplugged from its AC outlet
before working with any internal wiring.

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

!!!!!

5.

Tighten side panel grommet.

6.

Secure cabinet door and plug power
supply back in.

Line Cord Ground
Line Cord Neutral/Common
Line Cord Hot/Line

1TB-GROUND
1TB-N
1TB-L1

High V

High V

High V

High V

High Voltage Multiplier

oltage Multiplier

oltage Multiplier

oltage Multiplier

oltage Multiplier

1.

Remove HV cable from power supply.

2.

Ensure power supply is unplugged from
AC outlet and open cabinet door.

3.

Unplug connector 1PL from the top of
the high voltage multiplier.

4.

Remove the screws that mount the high
voltage multipliers’ aluminum housing to
the back panel.

5.

Disconnect 8PL and 10PL from 24 VDC
power supply 2SUP and remove (4)
mounting screws from the relay board.

6.

Rotate the high voltage multiplier assem-
bly out from the power supply.

7.

Remove the (3) screws that secure the
aluminum housing to the high voltage
multiplier.

8.

Install the aluminum housing on the new
high voltage multiplier (see "Parts Identi-
fication" section of this manual for order-
ing information). Ensure connector 1PL
faces the front of the housing before in-
stalling.

9.

Install the high voltage multiplier assem-
bly in the power supply by securing the
(6) mounting screws to the back panel.

10.

Plug connector 1PL back into the high
voltage multiplier, reconnect 8PL and
10PL to 24 VDC supply 2SUP and se-
cure the relay board.

!

Because the high voltage multiplier

contains energy storage components that
can cause serious shock injury, it is not
field repairable. Warranty will be voided if
the high voltage multiplier seal is broken. If
the high voltage multiplier is defective, con-
tact your authorized Ransburg representa-
tive for exchange or repair.