HRV and ERV Typical Installations (Deluxe Series)

8

2 Single Vents
SVE-50 and SVI-50
Shown.
“Fresh Air/ Exhaust Air
Vents Installation”

HRV/ERV (SUPERIOR)

RETURN-AIR DUCT

FURNACE

Wall Cap
Exhaust/Intake
WCE-5, WCI-5
shown

HRV/ERV

DVS100
Double Vent with hood shown “Fresh Air/Exhaust Air Vent installation”

Furnace Return Air-duct Connection

• This installation enables stale air to be drawn from the
poorest air quality areas of the home (washrooms & kitchen)

Double Vent with Extruded Aluminum Grille
DVG200 shown “Fresh Air/Exhaust Air Vent installation”

from washrooms
and kitchen

Semi Ducted System

• It is recommended that the furnace blower run continuously or HRV/ERV operation be interlocked with the furnace blower
to evenly distribute the fresh air throughout the house.

• A backdraft damper is required in the exhaust air duct to prevent outdoor air from entering the unit when the Furnace /
Air handler is running and the unit is in Standby, OFF or in Recirculation.

Note:

Typical Installations for House

Installation Options for High-Rise Condominium

Fully Ducted
System

With Fan-Coil
System

FRESH AIR
EXHAUSTED AIR

This is a stand alone HRV/ERV system which is not
connected to a force air system. Stale air is drawn from
key areas of the home (bathroom, kitchen) while fresh
air is supplied to main living areas.

Fully Ducted System

Above the
Snow line

Note:

All HRV / ERV must be balanced in the field. (Models: RHRV-D100A, RHRV-D100P and RERV-D100 c/w auto balancing are automatically balanced)

Note:

min. 5 ft away from sidewalls

.

All Exhaust Vents must be installed

Fan-coil Unit

HRV/ERV

Balancing Box

Fan-coil Unit

HRV/ERV

Distance

“X”

*Re - Circulation Efficiency
If distance “X” is 5ft - 99.7%
“X” is 3ft - 96.5%

•Fresh air from outside should be installed on
Fan-coil supply side (HRV/ERV station #2)
and HRV/ERV should be interlocked with
Fan-coil unit.