Step 1: replacing existing thermostat, Features – Robertshaw 9520 User Manual

Page 2

Advertising
background image

Features

• Multi-stage heating and cooling control

• Zone system compatible as a master thermostat

• Multi-colored LED indicators for system status

• Low battery indicator.

• Fahrenheit/Celsius display option.

• Adjustable from 45°F (4°C) to 90°F (32°C).

• Accuracy within ± 1 degree.

• Adjustable temperature differential: 1-3 degrees F.

• Automatic heating shutdown if temperature exceeds 90°F (32(C).

Step 1: Replacing Existing Thermostat

1. Turn off power to heating and cooling system.

2. Remove cover of old thermostat to expose wires. (Figure 1)

3. Disconnect wires one at a time from existing terminals. USE

ENCLOSED LABELS TO MARK EXISTING WIRES. Refer to cross refer-
ences in Table 1 if existing wiring does not directly match the labels.

If you have any questions about cross referencing the old terminal to
the new label, reference your equipment installation manual, a
licensed contractor, or call Robertshaw Tech Support (800) 445-8299

4. Remove existing thermostat base from wall.

2

Figure 1

Advertising