Robertshaw 9520 User Manual
Page 5

11. Terminal screws are loosened. Insert wires into terminal strip
(Figure 4) matching the label to the corresponding terminal
(see Wiring Diagrams below). Tighten screws.
5
Typical heat pump with cool active reversing valve and auxiliary/emergency heat.
O
B
9520 WIRING SAMPLE #1
Y1
E
G
W2
C
L
R
Y2
Typical heat pump with heat active reversing valve and auxiliary/emergency heat.
9520 WIRING SAMPLE #2
C
L
R
Y2
Y1
E
G
W2
O
B
Typical heat pump with heat active reversing valve and auxiliary/emergency heat.
Does not have separate wire for emergency heat (jump W2 & E).
9520 WIRING SAMPLE #3
B
Y1
E
G
W2
C
L
O
R
Y2
Jumper
Typical heat pump with cool active reversing valve, auxiliary/emergency heat
and second stage of cooling. System fault indicator connected (L terminal).
E
G
O
B
9520 WIRING SAMPLE #4
C
W2
L
R
Y2
Y1
FIGURE 4