A. Physical strength of mounting area. The structural integrity of mounting surfaces must be

strong enough to meet or exceed the holding force of the Magnalock.

B. Protection of the lock from external attack. The Magnalock and the wiring must be

protected to a reasonable degree from potential damage due to intruders or vandals.

C. Convenience and accessibility of area to be protected. The Magnalock assembly should be

installed in a location that will not hinder or create a potential safety hazard to authorized

personnel routinely accessing the protected area.

5.2. Magnalock Body and Strike Plate Installation
The exploded illustration below displays two mounting configurations available using the
hardware provided:

ITEM QTY

PART

NUMBER

NOMENCLATURE/DESCRIPTION

1 1 772-MCL-24

Magnalock

Body

2 1 390-17110

Universal

Bracket

3 1 380-20000

Strike

Plate

(MCL)

4 1 300-11620

#8-32 UNC X 1/2” Long Low Profile Socket Head
Cap Screw

5 2 310-11210

1/2” O.D. X 3/16” I.D. X .093” Neoprene Rubber
Washer

6

1

330-10670

3/32” O.D. X 1/2” Long Roll Pin

7

1

330-12170

Sex Bolt (#8-32 X 7/8” Binder Head)

8

3

300-11790

#10 X 3/4” Long (Phillips) Flat Head Screw

9

4

300-11645

#8-32 UNC X 3/4” Long Socket Head Cap Screw

10

4

300-11710

#6 X 1” Long (Phillips) Pan Head Screw

Mounting LOCK BODY with BRACKET

Mounting STRIKE PLATE with BRACKET

1

3

5

6

2

5

4

10

3

6

1

2

4

9

8

7

8