Securitron DK-12 User Manual

Page 2

Advertising
background image

PN# 500-24015

Page 2

Rev. C, 04/11

COMMAND LIST AND FORMAT
70 Turns on the double beeper chirp that sounds when the relay is energized by user code or

REX (not used in toggle or passage modes).

71 Turns off the double beeper chirp.
72 Turns on the key press single beeper chirp.
73 Turns off the key press single beeper chirp.
74 Reverses light logic (red to echo key presses and green to show relay is energized).
75 Returns light logic to normal (green to echo key presses and red to show relay is

energized).

79 Alternate code deletion. Any valid code entered will be deleted. You must press the ‘#’

key twice to complete the deletion.

88 Erases all user codes. You must press the ‘#’ key twice to complete the erasure. The

program code will not be deleted.

89 Returns all functions (including timer) to factory setting; all codes are unchanged. You

must press the ‘#’ key twice to complete the factory reset.

9 Followed by ‘00’ puts the relay in toggle mode.
9 Followed by ‘01’ through ‘99’ sets relay timeout in seconds.

PROGRAM CODE REPLACEMENT
During the initial installation of the DK-12, or if the program code is lost or unknown, the PCR
(Program Code Replacement) jumper can be used to enter programming mode. Once in
programming mode a new program code can be entered.

1. Disconnect the power supply.

2. Move the PCR jumper from the ‘OFF’ to the ‘ON’ position.
3. Apply power and both the yellow light will flash and the beeper will sound continuously.
4. Move the PCR jumper from the ‘ON’ to the ‘OFF’ position and the beeper will turn off; the

yellow light will continue to flash.

5. The DK-12 is now in programming mode.

FOR MORE DETAILS REGARDING YOUR SYSTEM

REFER TO THE INSTALLATION AND OPERATING INSTRUCTIONS.

Advertising