Securitron iMXDa_iEXDa QUICK START GUIDE User Manual

Page 3

Advertising
background image

PN# 500-22310

Page 3

Rev. B, 01/10

22.Pull on the assembly (strike) to align and engage the knurled potion of the sex bolt into the

hole.

23.While keeping the assembly aligned, use a hammer to tap the head of the sex bolt into place

and use a 3/16” hex key wrench in the socket head of the screw to tighten the assembly.

DO NOT OVERTIGHTEN THE STRIKE/SEX BOLT ASSEMBLY AS THIS CAN CAUSE

DAMAGE TO THE RUBBER WASHERS AND MAY PREVENT THE PROPER OPERATION

Actuator Mounting:
24.Drill the two (2) previously marked actuator mounting holes as instructed on the template.

25.Using a #2 Phillips screwdriver and the screws provided install the actuator to the door as

shown.

STEP 2 - MOUNTING THE LOCK HOUSING
Figures 3
and 4 below illustrate a typical lock housing installation on a steel door frame.

Figure 3

Figure 4

Step-by-step Mounting of the Lock Housing:
1. FOR METAL DOOR FRAME: Drill two (2) 3/8” [9.5mm] diameter holes and one 1/2”

[12.7mm] diameter hole at the three previously marked [A] hole positions on the frame.

Install two (2) 1/4-20 blind nuts into the 3/8” diameter holes. See the Installation and
Operating Manual
for details of how to install the blind nuts.

a. Using a #3 Phillips screwdriver and the two (2) 1/4-20 UNC X 1” long machine screws,

attach the lock mounting bracket to the frame.

2. FOR WOOD DOOR FRAME: Drill two (2) 3/16” [4.8mm] diameter holes X 1-1/4” [32mm]

deep (minimum) and one 1/2” [12.7mm] diameter hole through the frame at the previously
marked [A] hole positions.

a. Using a #3 Phillips screwdriver and two (2) #12 X 1-1/2” long Type “A” screws, attach the

lock mounting bracket to the frame.

3. Loosen the two (2) mounting screws enough to allow movement of the bracket.

4. Assemble the lock onto the bracket by shifting the unit to one side (approximately 1-1/2”

inches), engaging the top of the housing onto the bracket and then sliding it back toward
center as shown in Figure 4. Ensure that the lock is centered on the bracket.

5. Adjust the lock (and bracket) into position making contact with the face of the strike.

6. Mark the door frame at each end of the assembly to indicate the position of the mounting

bracket and then carefully remove the lock from the bracket.

7. As necessary, re-align the bracket to the position marks, then using a screwdriver fully

tighten the two bracket mounting screws.

8. Using the mounted bracket as a guide, center punch the frame at the four (4) remaining

mounting holes marked [B] on the template.

9. FOR METAL DOOR FRAME: Drill four (4) 3/16” [4.8mm] diameter holes through the frame.

a. Using a #3 Phillips screwdriver and four (4) #12 X 1-1/2” long Type “A” screws fully

secure the bracket to the frame.

10.FOR WOOD DOOR FRAME: Drill four (4) 7/32” [5.5mm] diameter holes X 2-3/4” [70mm]

deep (minimum) into the frame.

a. Using a #3 Phillips screwdriver and four (4) #14 X 3” long Type “A” screws fully secure

the bracket to the frame.

Blind Nuts

Mounting Hole

Dress Plugs

SFP Bracket

(Not Included)

Mounting

Bracket

Lock Housing

Door Frame & Stop

Mounting

Screws

Advertising