MATRIX #1: Switch 2 Off; Switch 3 Off nuisance delay disabled

MATRIX #2: Switch 2 On; Switch 3 Off: (factory set): 1 second nuisance delay

MATRIX #3: Switch 2 Off; Switch 3 On: 2 second nuisance delay

MATRIX #4: Switch 2 On; Switch 3 On: 3 second nuisance delay


Switch 4: This implements BOCA timed relocking (see the chart in Section 2). In the factory set
(Off) position, standard relocking from either the integral keyswitch (manual relocking) or from
the door being used (automatic relocking) is implemented. When the switch is turned On, 30
second delayed BOCA relocking is set. Under some conditions, local authorities may require a
45 second delayed BOCA relocking. The standard control board does not support this. Contact

the factory to order a modified board with the 45 second feature.

Switch 5: This selects manual or automatic relocking. In the factory set (off) condition, the
door is relocked from a momentary turn of the integral keyswitch. Turning the switch on selects
automatic relocking from use of the door. Note that when BOCA relocking is selected (Switch 4,

On), this switch setting is ignored because BOCA relocking is always automatic.

3. PHYSICAL INSTALLATION
3.1 DETERMINING HORIZONTAL OR VERTICAL MOUNT AND APPLYING TEMPLATE
The iMXD can be mounted horizontally under the frame header or vertically along the frame.

Once you have selected the orientation for your installation, apply the template to set your
hole drilling positions. To apply the template, close the door (be sure it latches) and note that
the template has a folding line on it. The magnet housing “sub-plate” is on one side of the line
and the strike plate/permanent magnet bracket is on the other. Position the fold in the template
along the edge the door stop makes with the door surface so that the sub-plate portion of the

template extends on to the door stop and the strike/permanent magnet bracket portion extends
on to the door surface. If you have a swing through type aluminum frame glass door,
there is no door stop so you simply position the template fold line on the edge between the door
surface and frame stile. In planning your installation for this type of door, a special
consideration comes into play. First, before drilling any holes, you want to be sure that the
aluminum door rail is wide enough to support the sex bolt
. The iMXD sex bolt is 1”

(25MM) diameter which is much thicker than normal magnetic lock sex bolts. This type of door
is made with extrusion widths which vary widely but some are so narrow that you can only
mount the MXD sex bolt when you are using the offset strike. The offset strike relocates the
central strike mounting hole by ¼”. It is available from the factory.

To determine in advance whether your door will accept the MXD sex bolt, just hold the template
so that you can visually see the center point of where the sex bolt will go into the door rail.
Assure yourself that a 1” diameter hole around this point will not strike the glass or any support
rods internally.

Note: if you have an aluminum frame glass door with a blade stop, see the next section as the
template is used differently. Otherwise, the template will work on horizontal or vertical mounts
and on left hand or right hand doors but be sure that the edge of the template is flush to the
corner of the door stop for best mounted appearance (the iMXD housing will reach to the corner
of the door stop).

Tape the template into position and using a center punch, mark the hole locations on the door
and frame. The template will indicate the number and positions of the hole locations as well as
the hole diameters. Note that if the door stop is narrow, you may need to add a filler plate to
create a wide enough mounting surface for the sub-plate.

3.2 TEMPLATE USE ON AN ALUMINUM FRAME GLASS DOOR WITH BLADE STOP
A blade stop is so narrow (around 1/8”) that nothing can be mounted on it. Therefore, you
cannot place the folded edge of the template in the corner made by the stop and door surface as
you will not be mounting on the stop. You will be mounting the sub-plate adjacent to the stop
directly on the frame extrusion. To use the template in this exceptional situation, cut it with a

scissors along the fold line. To mark the strike plate/permanent magnet bracket holes, open the
door slightly and insert the template behind the blade stop until it just touches the door frame.