Securitron EXD User Manual

Page 7

Advertising
background image

PN# 500-13350

Page 7

Rev. E, 11/11


Switch 1: This sets the amount of time for
release delay. In the factory set (Off)

position, release delay is set for 15
seconds. Turning the switch On sets a 30
second release delay.

Switch 2 and 3: The combined position of

the 2 switches selects 4 different values
for nuisance delay.

MATRIX #1: Switch 2 Off; Switch 3 Off (factory set): nuisance delay disabled

MATRIX #2: Switch 2 On; Switch 3 Off: 1 second nuisance delay

MATRIX #3: Switch 2 Off; Switch 3 On: 2 second nuisance delay

MATRIX #4: Switch 2 On; Switch 3 On: 3 second nuisance delay


Switch 4: This implements BOCA timed relocking (see Section 4.4). In the factory set (Off)
position, standard relocking from a momentary reset switch is implemented. When the switch is
turned On, 30 second delayed BOCA relocking is set. Under some conditions, local authorities

may require a 45 second delayed BOCA relocking. The standard XDT board does not support
this. Contact the factory to order a modified board with the 45 second feature.

FIG 2: TYPICAL WIRING, EXD SYSTEM

WITH TOUCH SENSE BAR OR TOUCH SENSE PLATE

LED

MK

KEYSWITCH

TSB-3

OR

TSH

MAGNALOCK

NC

C3

NO

NC

C2

NO

NC

C1

NO

XDT BOARD

IF DOORSWITCH

REPLACES KEYSWITCH
IT MUST BE CLOSED

WHEN DOOR IS CLOSED

REMOTE ALARM

RELAY

RED

BL
A

C

K

SONA-

LERT

RED

GREEN

RED

GRN

WHT

RED

BL
A

C

K

+

V+

RS

IN
FE

BP

LS

+

BLACK

WHITE

BLUE

0V (NEG)

FR

O

M

PO

W

E

R

S

U

PP

LY

DIP

SWITCHES

0N

OF

F

1
2
3

4

FACTORY SETTINGS SHOWN IN BLACK

BOCA RELOCKING

STANDARD RELOCKING

MATRIX (SEE TEXT)
MATRIX (SEE TEXT)

MATRIX (SEE TEXT)

MATRIX (SEE TEXT)

15 SEC. RELEASE DELAY

30 SEC. RELEASE DELAY