4 Installation/Wiring/Setup (Continued)

5 Troubleshooting

3

Setup

Potentiometer

Output Mode Switch

24”

4”

Pulse Mode

Toggle Mode

4”

24”

WSS

Sensing Field

1. Adjust unit to desired setup. Two adjustments can

be made to the sensor. The Potentiometer is used

to adjust the size of the units’ sensing field and the

Output Mode switch is used to select Toggle or Pulse

mode.

2. Rotate potentiometer clockwise to increase the sensing

field. It may be adjusted from 4” to 24”.

3. Adjust Output Mode by moving switch in the up position

(Toggle Mode) or in the down position (Pulse Mode).

Toggle Mode: Recommended for switch applications. In

Toggle mode a detection activates the relay

and a second detection deactivates the

relay.

Pulse Mode: Recommended for automatic door

applications. In Pulse mode a detection

activates the relay for a short period of time

- depending on the duration of movement in

front of door.

1

Troubleshooting Procedures

PROBLEM

PROBABLE CAUSE

CORRECTIVE ACTION

Door does not open when swiping

hand in front of sensor.

1. Bad or no power supply.

2. Detection range is too small.

3. Wrong connection.

1. Check power supply. If LED

switches on or flashes, power

connections are OK.

2. Adjust the detection range.

Remove any metal plates in

front of sensor.

3. Check wiring and relay

connection.

Door remains permanently open.

1. Environmental conditions are

influencing the sensor.

2. Wrong connection.

1. Remove any moving objects

close to the sensor.

2. Check wiring and relay

connection.

The door remains open after

detection/activation

1. Wrong output mode.

2. Wrong connection

1. Switch the output mode to

Pulse mode.

2. Check wiring and relay

connection.

FCC APPROVAL

This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.

Operation is subject to the following two conditions:

1. This device may not cause harmful interference, and

2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide

reasonable protection agianst harmful interference in a residential installation. This equipments generates, uses and can radiate radio frequency energy and, if not installed and

used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular

installation. If this equipment does not cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is

encouraged to try to correct the interference by one or more of the following measures:

*Reorient or relocate the receiving antenna

*Increase the separation between the equipment and receiver

*Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

*Consult the dealer or an experienced radio/TV technician for help

WARNING: CHANGES OR MODIFICATIONS TO THIS EQUIPMENT NOT EXPRESSLY APPROVED BY BEA INC. MAY VOID THE FCC AUTHORIZATION TO OPERATE THIS EQUIPMENT.